Extraoral Dental Radiographs: Types, Indications, and Technique

Extraoral radiographs are dental imaging modalities where the film or digital sensor is positioned outside the mouth, as opposed to intraoral radiographs (periapical, bitewing, occlusal) where the receptor is placed inside the oral cavity.

Types of Extraoral Radiographs

1. Panoramic Radiograph (Panorex, Orthopantomogram - OPG)

  • Principle: Rotating tube-detector pair around patient's head; tomographic section of jaws
  • Image: Entire maxilla, mandible, TMJs, sinuses, nasal cavity in single image
  • Indications: Third molar assessment, orthodontic planning, trauma survey, pathology screening, implant planning (preliminary), edentulous ridges
  • Limitations: Magnification (~25%), distortion, superimposition, poor anterior detail, no caries detection

2. Cephalometric Radiograph (Ceph, Lateral Cephalogram)

  • Principle: Fixed head position (cephalostat), standardized geometry (5 ft source-object)
  • Image: Lateral (standard) or PA skull — craniofacial skeleton, soft tissue profile
  • Indications: Orthodontic diagnosis, growth prediction, surgical planning, airway assessment
  • Analysis: Tracing/digitization → angular/linear measurements (Steiner, Ricketts, McNamara, etc.)

3. Cone Beam CT (CBCT)

  • Principle: Cone-shaped X-ray beam, area detector, 360° rotation → 3D volumetric data
  • Image: Isotropic voxels (0.075-0.4 mm), multiplanar reconstruction, 3D rendering
  • Indications: Implant planning, impacted teeth/nerve relation, pathology, TMJ, airway, trauma, endodontic complexity
  • Advantage: 3D, low dose vs. medical CT, high spatial resolution
  • Limitation: Soft tissue contrast, scatter artifacts, higher dose than 2D extraoral

4. Posteroanterior (PA) Skull / Waters View / Submentovertex

  • Supplemental skull views for trauma, sinus, facial bone assessment
  • Largely replaced by CBCT for 3D needs

5. Hand-Wrist Radiograph

  • Skeletal age assessment (Greulich-Pyle, Tanner-Whitehouse) for orthodontic timing
  • Extraoral — film/sensor on hand, not in mouth

Technical Factors

ParameterTypical Range
kVp60-90 (pan/ceph); 60-120 (CBCT)
mA5-15 (pan/ceph); 3-10 (CBCT)
Exposure Time10-20 sec (pan); 0.5-3 sec (CBCT scan)
Effective Dose10-25 µSv (pan); 5-15 µSv (ceph); 30-100+ µSv (CBCT)

Film/Sensor Positioning

  • Panoramic: Sensor in rotating cassette/detector — patient bites bite-block, chin rest, head positioned via laser guides
  • Cephalometric: Sensor in cassette at fixed distance; ear rods, nasion guide position head
  • CBCT: Area detector fixed; patient stands/sits, chin rest, bite index for region of interest

Radiation Protection

  • ALARA: Selective indication — not routine screening
  • Thyroid collar: Mandatory for panoramic/ceph (reduces thyroid dose 40-50%)
  • Lead apron: Standard
  • Collimation: CBCT field of view (FOV) limited to region of interest
  • Pregnancy: Avoid unless urgent; shield abdomen if necessary

Clinical Decision: Intraoral vs. Extraoral

Clinical QuestionPreferred Modality
Interproximal cariesBitewing (intraoral)
Periapical pathologyPA (intraoral)
Third molar positionPanoramic ± CBCT
Orthodontic diagnosisCeph + Pan ± CBCT
Implant planningCBCT (mandatory)
Trauma (mandible)Pan ± CBCT
Sinus/airwayCBCT

Key point: Extraoral radiographs complement — not replace — intraoral imaging. Selection follows ALARA: the exam that answers the clinical question with the lowest reasonable dose.