Jandy AquaPure 1400 Service Code 180: Low Flow Troubleshooting Steps
Code 180 = insufficient water flow through the salt chlorinator cell.
Troubleshooting Checklist
- Filter: Clean or replace; dirty filter restricts flow.
- Pump: Verify running at programmed speed; check for air leaks, impeller debris.
- Bypass valve: Must be fully open; partial closure starves cell.
- Cell: Inspect for scale/debris; clean per manual (acid wash if needed).
If all above are correct and code persists, contact Jandy support—may be a flow sensor or control board issue.