Bilirubin Specimen Handling: Pre-Analytical Requirements
Critical Pre-Analytical Steps
- Light Protection: Bilirubin is photo-labile. Collect in amber tubes or wrap clear tubes immediately in foil/light-protective sleeve. Transport and process in dim light.
- Anticoagulant: EDTA (lavender top) preferred for plasma; serum (red/gold top) acceptable if processed rapidly. Heparin may interfere with some assays.
- Centrifugation: Spin within 15 minutes of collection at 3000–3500 × g for 10 min to separate plasma/serum from cells (ongoing cellular metabolism consumes bilirubin).
- Aliquoting: Transfer supernatant to amber secondary tube within 1 hour. Label with patient ID, date/time, “protect from light.”
- Storage: Refrigerate (2–8°C) if analyzed ≤24 hrs; freeze (–20°C) for longer. Avoid freeze-thaw cycles.
Why It Matters
Light exposure degrades bilirubin → falsely low results → missed hyperbilirubinemia (neonatal kernicterus risk, Gilbert’s, hemolysis, obstructive jaundice). Strict adherence ensures diagnostic accuracy.