Calculating True Urine Output During Continuous Bladder Irrigation (Cystoclysis)

During continuous bladder irrigation (CBI), the drainage bag collects both urine and irrigation fluid. To determine the patient’s actual urine output:

Formula

Actual Urine Output = Total Drainage Volume − Volume of Irrigation Fluid Instilled

Practical Steps

  1. Record total volume in drainage bag at set intervals (e.g., hourly).
  2. Record exact volume of irrigation solution infused during same interval (from irrigation bags).
  3. Subtract infused volume from total drainage.
  4. Document as “Urine Output (CBI)” to distinguish from standard output.

Example

  • Irrigation infused: 3,000 mL over 4 hours.
  • Total drainage: 3,400 mL.
  • Actual urine output: 3,400 − 3,000 = 400 mL (100 mL/hr).

Clinical Notes

  • Ensure irrigation runs continuously; pauses invalidate calculation.
  • Monitor for clots obstructing outflow—sudden drop in drainage with ongoing irrigation suggests blockage.
  • Target urine output typically ≥30 mL/hr (adults); adjust irrigation rate per physician order to maintain clear, light pink return.
  • Document irrigation fluid type (normal saline, glycine, sorbitol) as it affects electrolyte absorption.