Calculating True Urine Output During Continuous Bladder Irrigation (Cystoclysis)
During continuous bladder irrigation (CBI), the drainage bag collects both urine and irrigation fluid. To determine the patient’s actual urine output:
Formula
Actual Urine Output = Total Drainage Volume − Volume of Irrigation Fluid Instilled
Practical Steps
- Record total volume in drainage bag at set intervals (e.g., hourly).
- Record exact volume of irrigation solution infused during same interval (from irrigation bags).
- Subtract infused volume from total drainage.
- Document as “Urine Output (CBI)” to distinguish from standard output.
Example
- Irrigation infused: 3,000 mL over 4 hours.
- Total drainage: 3,400 mL.
- Actual urine output: 3,400 − 3,000 = 400 mL (100 mL/hr).
Clinical Notes
- Ensure irrigation runs continuously; pauses invalidate calculation.
- Monitor for clots obstructing outflow—sudden drop in drainage with ongoing irrigation suggests blockage.
- Target urine output typically ≥30 mL/hr (adults); adjust irrigation rate per physician order to maintain clear, light pink return.
- Document irrigation fluid type (normal saline, glycine, sorbitol) as it affects electrolyte absorption.
Urine Therapy - Related Articles
- Laennec vs. MF3 HP Human Placenta Injections: Key Differences
- Kidney Function and Urine Formation: Filtration, Reabsorption, Secretion, and Excretion
- The Renal Tubule: Blood Filtration, Reabsorption, and Urine Formation
- Blood in Urine After Ureteral Stent Placement: Duration, Causes, and Management
- Human Excretory Products: Beyond Urine
- Frequent Urination and Leakage: Causes, Evaluation, and Management
- Calculating True Urine Output During Continuous Bladder Irrigation (Cystoclysis)