Systolic Blood Pressure: The First Korotkoff Sound in Blood Pressure Measurement
The first distinct, rhythmic tapping sound heard during manual blood pressure measurement (auscultatory method) corresponds to systolic blood pressure (SBP)—the peak arterial pressure during left ventricular systole.
Korotkoff Sounds
| Phase | Sound Quality | Pressure |
| Phase I | Clear, sharp, repetitive tapping | Systolic BP |
| Phase II | Swishing/murmuring | — |
| Phase III | Crisper tapping, louder | — |
| Phase IV | Abrupt muffling, blowing | Diastolic (older definition) |
| Phase V | Sound disappearance | Diastolic BP (current standard) |
Physiological Basis
- Cuff pressure > SBP: Artery occluded → no flow → silence
- Cuff pressure = SBP: Intermittent flow → turbulent jets → Korotkoff sounds begin
- Cuff pressure < DBP: Continuous laminar flow → silence
Measurement Best Practices
- Validated, calibrated device (automated oscillometric preferred for routine)
- Correct cuff size (bladder 80% arm circumference, 40% width)
- Patient seated 5 min, back supported, feet flat, arm at heart level
- No caffeine, exercise, smoking 30 min prior
- Two readings 1–2 min apart; average
- Diagnose hypertension on ≥2 visits (except hypertensive urgency/emergency)
Clinical Significance of SBP
- Major cardiovascular risk factor (especially >50 years)
- Isolated systolic hypertension (ISH) common in elderly (stiff arteries)
- Treatment target: <130 mmHg (ACC/AHA); individualized for frail elderly
- Pulse pressure (SBP − DBP) widens with arterial stiffness
Special Situations
- Ausculatory gap: Sounds disappear/reappear (stiff arteries) — inflate 30 mmHg above estimated SBP
- Pseudohypertension: Non-compressible arteries (Monckeberg's) → falsely high cuff pressure
- White coat hypertension: Elevated in office, normal out-of-office (ABPM/HBPM confirm)
Accurate SBP identification is foundational to cardiovascular risk assessment and hypertension management.